The Town of Frankford
The Town of Frankford, Delaware is located in Sussex County. It is approximately 10 miles west of the Atlantic coastline at Bethany Beach. According to 2010 U.S. Census Data on Frankford, the population is 847. It is a relatively young population and grew 18.6 percent from 2000 to 2010. There are 252 households in Frankford, and 152 of these households are owned by the occupants.
History Of Frankford
The area was populated as early as 1750 under the local name of Forest Flower. In 1775, it was deeded to a plantation in a land grant under the name of Partnership. It became known as Jacob’s Mill Pond around 1800. In 1808, the community became commonly known as Long’s Store on Vine’s Branch when plantation owner David Long constructed a country store at the location. Many people knew the area as Gum’s Store in 1812. This is presumably because the ownership of the store had changed, but the precise details are not clear. It became known as Frankford around 1820 and was officially given that name in 1848 when a post office was established at Frankford Village. The Town of Frankford became an incorporated municipality in 1337.
The arrival of the Pennsylvania Railroad heralded rapid growth in Frankford. A hotel opened, as did a local opera house, and Frankford became the center for business and cultural events in the area. Noteworthy sea captains made their homes in Frankford, and three of those homes are still in existence. In 1979, the Captain Ebe Townsend Chandler house was added to the National Register of Historic Places. It now operates as the Captain Chandler House Bed and Breakfast Inn.
Area Attractions
The Assawoman Bay State Wildlife Area, a popular destination for East Coast birdwatchers, is located seven miles east-southeast of Frankford. An observation tower and photography blind are located within the wildlife area, and loblolly pine forests make it a refuge for land birds as well as the expected waterfowl.
The Delaware Seashore State Park, nearly 3,000 acres of beaches and a barrier island, is located just 10 miles to the east of Frankford. The park is open to Delaware’s Atlantic Coast on the east and bounded by the bays of the Rehoboth and Indian Rivers to the west. It is a major attraction in the region and receives millions of visitors each year.
Frankford is also quite close to the Pocomoke State Forest. This forest, which has a plan to become a national model for certified sustainable forestry, is comprised of 17,676 acres of land that was once cleared for farming. The land was reacquired by the federal government during the Great Depression and deeded to Delaware in 1954. The park contains approximately five acres of old growth forest that had escaped felling when the area was farmed.
Furnace Repair and Service
We offer a range of services including furnace repair and installations, designed to help your HVAC equipment perform more efficiently. Whenever you're ready for a repair or installation, safety inspection or seasonal maintenance visit, our service techs are available on your schedule.
Air Conditioning Service In Frankford
Air conditioning service in Frankford is probably an afterthought for most residents. The region is not known for uncomfortably hot summers. Delaware averages almost 100 days per year with temperatures below freezing and only 20 days with temperatures of 90 degrees or higher. However, 2012 was the hottest overall year on record for Delaware, and 2010 was the hottest summer on record. The average temperature for the summer of 2010 was 78.1 degrees Fahrenheit.
If you need air conditioning repairs, Custom Mechanical stands ready to deliver. They have a fleet of more than 20 vehicles and offer heating, plumbing, and carpentry work in addition to their cooling service. Custom Mechanical is a family owned and operated business and has been providing fast, reliable service to customers for over 30 years.
Recent Jobs and Reviews in Frankford, DE
Frankford, DE at a glance
Custom Mechanical has completed 20 jobs in Frankford, DE in April 2026.
The most recent job was on April 28, 2026.
Job Locations and Reviews
Performed comprehensive evaluation of second-floor HVAC system in approximately 5-year-old residence experiencing temperature control issues with excessive heat in summer and insufficient heating in winter. Inspected attic-installed air handler unit and associated ductwork system, documenting equipment condition and installation configuration. Provided homeowner with multiple options to improve temperature consistency and comfort levels on upper floor, including potential IAQ enhancements and system modifications to address thermal imbalance concerns.
Completed plumbing installation in bathroom, finalizing all fixture connections and ensuring proper operation of toilet water supply lines. Verified all components were securely installed, tested for leaks, and confirmed bathroom was left in clean, functional condition with all fixtures properly positioned and operational.
Completed scheduled cooling maintenance visit on residential HVAC system. Performed comprehensive system inspection including electrical diagnostics with clamp meter, verified capacitor functionality and connections, and confirmed proper amperage readings at 23.55 amps. Inspected condenser unit components including coil condition and verified thermostat operations on both Honeywell Home ProSeries and Aprilaire units, which were displaying proper temperature readings and functioning in auto fan mode. All system components operating within normal parameters with no deficiencies noted.
Relocated and reinstalled air handler unit in closet following completion of plumbing work. Cut out drywall ceiling section to accommodate repositioning of upstairs refrigerant lines, then covered opening with flat metal panel above duct fittings. Installed plywood base under existing return plenum to prepare for future flooring installation. Repositioned air handler to right side of closet with service panels facing left to create clearance in recessed area. Relocated lineset to back wall of closet to accommodate new air handler placement. Installed new electrical disconnect on left side of closet and ran power wire across interior closet wall above door to air handler connection point.
Completed routine cooling maintenance visit on HVAC system. Performed comprehensive system inspection, checked refrigerant levels and pressures using digital manifold gauge, verified proper operation of all components, and documented equipment conditions with photos. System operating within normal parameters.
Completed cooling system maintenance inspection and performance verification. Measured blower motor amperage at 193 amps using clamp meter, checked electrical connections at control board, and inspected blower assembly for proper operation. Customer has adequate filter supply remaining on-site.
Performed comprehensive system inspection and tune-up on single HVAC unit. Verified thermostat operation and programming settings, confirmed proper communication with system, and tested temperature control functionality. Conducted diagnostic measurements using digital testing equipment to ensure system operating within manufacturer specifications.
Conducted comprehensive assessment of existing 2017 HVAC system installed in attic space for full system replacement estimate. Evaluated air handler unit, refrigerant lines, electrical connections, ductwork configuration, and condensate drainage system to determine specifications and requirements for complete replacement installation. Documented current equipment conditions and spatial considerations to provide accurate system replacement proposal.
Performed preventive maintenance on residential cooling system. Inspected and documented condition of air handler filter, which showed significant dust and debris accumulation requiring attention. Also completed maintenance service on tankless water heater as part of comprehensive system check.
Completed preventive maintenance cooling visit on residential HVAC system. Verified thermostat operation showing proper temperature control and programming functionality, confirmed 24-volt control circuit voltage at outdoor unit measuring 24.5 volts, and inspected all electrical connections and wiring terminals for secure contact and proper operation.
Completed routine cooling maintenance visit on multi-system property. Inspected outdoor condenser unit, verified proper operation, and documented electrical panel configuration. All systems operating within normal parameters with no deficiencies noted at time of service.
Completed full HVAC system replacement including installation of Carrier 27SCA536A003 3-ton 15 SEER heat pump, Carrier FT5ANBC36L00 variable speed air handler with 10kW electric heat pack, and Honeywell S1200 thermostat in black. Removed and disposed of existing equipment, with outdoor unit temporarily removed to allow contractor access for stand repair before final placement. Installed new outdoor disconnect and electrical whip, reused existing condensation and power lines, and fabricated metal duct transitions to adapt to existing ductwork. Rerouted flex duct line to improve airflow distribution to bedroom while maintaining system efficiency, positioned outdoor unit on repaired stand with proper clearance, and verified all electrical connections and refrigerant lines for proper operation.
Performed comprehensive cooling system inspection and maintenance on HVAC unit. Conducted operational diagnostics using digital thermometer and clamp meter, measuring system temperatures and electrical parameters to verify proper performance. Return air temperature recorded at 61.8°F, with electrical readings at 498 on the multimeter indicating normal amperage draw. Inspected all electrical connections, wiring, and blower assembly within the air handler unit. Additionally, performed tankless water heater maintenance including system flush to remove mineral buildup and ensure optimal efficiency.
Removed and disposed of existing HVAC equipment from basement utility space. Installed new Lennox ML14KP1-024 2-ton 14 SEER heat pump system with Lennox CBK45UHET-024 air handler and 10 kW electric heat pack in attic space. Fabricated and installed metal duct transitions to adapt new equipment to existing ductwork system. Mounted air handler on plywood platform with proper support and secured all ductwork connections with reflective foil-faced insulation for thermal efficiency. Installed Honeywell standard two-zone zone board to enable multi-zone climate control throughout the home. Reused existing thermostats and integrated them with new zone control system. Replaced outdoor electrical disconnect and whip to meet current code requirements for new heat pump unit. Positioned outdoor heat pump unit on pressure-treated wood platform to ensure proper drainage and equipment longevity. Reused existing refrigerant lines, condensate drain lines, and power supply connections where applicable
Completed preventive maintenance cooling inspection on first of two HVAC systems. Performed comprehensive electrical diagnostics using clamp meter to measure amperage draw on outdoor condensing unit. Accessed electrical compartment and tested capacitor, contactor, and associated wiring connections. Verified proper current readings at 0.59 amps during diagnostic testing. Inspected all electrical components including capacitor, relay, and wire terminations for signs of wear or damage. All components operating within normal parameters. System tested and confirmed operational. Unit left in proper working condition. Second system inspection to follow as part of scheduled maintenance visit.
Responded to no cooling call with indoor temperature at 83°F. Upon arrival, system was not operating. Troubleshot electrical circuit and identified tripped breaker Q150 at main panel. Reset breaker and verified system startup, restoring cooling operation. Inspected air handler and ductwork in attic space, confirmed proper airflow through supply plenum and verified refrigerant lines were intact with insulation in acceptable condition.
Completed comprehensive heating maintenance visit on residential HVAC system. Performed diagnostic testing including supply air temperature measurements (52.7°F recorded) and electrical current readings (0.64A) at blower motor assembly. Inspected ductwork, motor connections, and system components in accordance with preventive maintenance protocol. System operating within normal parameters. Scheduled follow-up cooling maintenance visit for April 16, 2026.
Performed preventive maintenance on cooling system. Verified electrical amperage draw at 5.17 amps using clamp meter and confirmed supply air temperature at 72.5°F at ductwork. System operating within normal parameters with no deficiencies noted.
Completed preventative maintenance inspection on two cooling systems. Performed diagnostics in attic space, including temperature and airflow measurements on insulated ductwork using digital testing equipment to verify proper system operation and efficiency.
Performed cooling system maintenance inspection and diagnostics. Utilized digital measurement instruments to assess system performance parameters including temperature differentials and airflow measurements at various points throughout the HVAC system. All readings documented and system found to be operating within normal parameters.