Reliable HVAC Services Near Ocean Pines, MD

  • NATE-Certified Technicians
  • Fast Local Response
  • Upfront Pricing & Honest Recommendations
  • Repairs, Replacements & Maintenance Plans
(877) 696-0808

Request An Appointment

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Name*
Special Offers
By submitting this form and signing up for texts, you agree to receive informational messages (appointment reminders, account notifications, etc.) from Custom Mechanical at the number provided. Msg & data rates may apply. Msg frequency varies. Unsubscribe at any time by replying STOP and no further messages will be sent. Reply HELP for help. For more information checkout our Privacy Policy.

Ocean Pines, MD

Ocean Pines, MD, is one of the Eastern Shore's most established planned communities. It's a place where well-kept homes, tree-lined streets and year-round residents create something rarer than a beach town: a genuine neighborhood. And like any neighborhood worth living in, comfort matters here in every season. From the sticky stillness of a July afternoon to the raw, grey chill of a mid-Atlantic January, Custom Mechanical has been the Delmarva region's trusted partner in heating and air conditioning since 1981. We don't only show up when something breaks. We help Ocean Pines, MD, homeowners build a comfort system that performs reliably, efficiently and affordably all year.

Dependable 24/7 Furnace Repair and Installation in Ocean Pines, MD

Ocean Pines, MD, sits far enough inland from the Atlantic to catch the full force of Maryland's winter weather, and a furnace that isn't operating at full capacity makes those months far more miserable. Inconsistent heat distribution, unusual cycling patterns, banging sounds and rising gas bills are all early warning signs that your heating system needs professional attention. Custom Mechanical's licensed service technicians diagnose and repair all major furnace brands, addressing everything from cracked heat exchangers and faulty ignition systems to failing blower motors and blocked flue pipes. When repair no longer makes financial sense, we handle complete furnace installations with the same care and precision that Ocean Pines, MD, homeowners have come to expect from our team.

Upgrade Your Comfort With a Heat Pump Installation in Ocean Pines, MD

For Ocean Pines, MD, homeowners looking to consolidate their heating and air conditioning into one intelligent, energy-efficient system, a modern heat pump installation is one of the smartest investments available. Heat pumps deliver both heating and cooling from a single system, eliminating the need to maintain two separate systems while dramatically reducing energy consumption year-round. Custom Mechanical is experienced in sizing, installing, and servicing heat pumps from all leading manufacturers, including Carrier, and our service technicians take the time to match each system to the specific thermal profile of your home. For a community of well-built, year-round residences like Ocean Pines, MD, a heat pump upgrade is a long-term financial investment.

24/7 Water Heater Repair and Installation in Ocean Pines, MD

Home comfort extends well beyond heating and cooling, and Custom Mechanical has always understood that. As a full-service residential provider, we bring the same level of expertise that Ocean Pines, MD, homeowners trust for air conditioning repair and heating service to their water heater needs as well. Water heater performance is one of the most overlooked contributors to daily home comfort; an aging or undersized water heater leads to cold showers, inconsistent hot water supply and energy waste that adds up over time. Custom Mechanical handles water heater repair, replacement and installation.

Do you need heating and air conditioning services in Ocean Pines, MD? Or maybe you need a water heater installation or repair. Contact Custom Mechanical to get started.

Recent Jobs and Reviews in Ocean Pines, MD

Job Locations and Reviews

Responded to a blockage affecting a toilet and bathtub in a 1970s-era home. Located and accessed the exterior sewer cleanout, which showed signs of debris accumulation and weathering. Successfully cleared the obstruction through the cleanout access point, restoring proper drainage to both affected fixtures.
Responded to a blockage affecting a toilet and bathtub in a 1970s-era home. Located and accessed the exterior sewer cleanout, which showed signs of debris accumulation and weathering. Successfully cleared the obstruction through the cleanout access point, restoring proper drainage to both affected fixtures.
Kenneth N.
Kenneth N. Checked in
Responded to a blockage affecting a toilet and bathtub in a 1970s-era home. Located and accessed the exterior sewer cleanout, which showed signs of debris accumulation and weathering. Successfully cleared the obstruction through the cleanout access point, restoring proper drainage to both affected fixtures.
Ocean Pines, MD 21811
Removed existing mini split head unit and cut drywall behind wall bracket to inspect insulation and perform air sealing. Resecured drywall, installed new wall bracket to cover cutout, and mounted new MSZWX12NL wall hung air handler unit with refrigerant lines and electrical connections completed per manufacturer specifications.
Removed existing mini split head unit and cut drywall behind wall bracket to inspect insulation and perform air sealing. Resecured drywall, installed new wall bracket to cover cutout, and mounted new MSZWX12NL wall hung air handler unit with refrigerant lines and electrical connections completed per manufacturer specifications.
Frankie C.
Frankie C. Checked in
Removed existing mini split head unit and cut drywall behind wall bracket to inspect insulation and perform air sealing. Resecured drywall, installed new wall bracket to cover cutout, and mounted new MSZWX12NL wall hung air handler unit with refrigerant lines and electrical connections completed per manufacturer specifications.
Ocean Pines, MD 21811
Installed new insulated metal return plenum with integrated filter rack and 16x20x1 filter for attic-mounted air handler. Leveled unit, installed emergency safety switch trap, and sealed air leaks at unit connections including 4" cap installation. Inspected and cleaned evaporator coil to restore proper airflow and system efficiency.
Installed new insulated metal return plenum with integrated filter rack and 16x20x1 filter for attic-mounted air handler. Leveled unit, installed emergency safety switch trap, and sealed air leaks at unit connections including 4" cap installation. Inspected and cleaned evaporator coil to restore proper airflow and system efficiency.
Federico P.
Federico P. Checked in
Installed new insulated metal return plenum with integrated filter rack and 16x20x1 filter for attic-mounted air handler. Leveled unit, installed emergency safety switch trap, and sealed air leaks at unit connections including 4" cap installation. Inspected and cleaned evaporator coil to restore proper airflow and system efficiency.
Ocean Pines, MD 21811
Responded to service call for disconnected and damaged flexible ductwork in crawl space initially identified by plumber. Upon inspection, found section of flex duct detached from supply vent with torn and shredded insulation jacket. Reattached ductwork to register boot, secured connections with appropriate fasteners and mastic sealant, and replaced damaged insulation sections to restore proper airflow and thermal efficiency to affected zone.
Responded to service call for disconnected and damaged flexible ductwork in crawl space initially identified by plumber. Upon inspection, found section of flex duct detached from supply vent with torn and shredded insulation jacket. Reattached ductwork to register boot, secured connections with appropriate fasteners and mastic sealant, and replaced damaged insulation sections to restore proper airflow and thermal efficiency to affected zone.
Dennis K.
Dennis K. Checked in
Responded to service call for disconnected and damaged flexible ductwork in crawl space initially identified by plumber. Upon inspection, found section of flex duct detached from supply vent with torn and shredded insulation jacket. Reattached ductwork to register boot, secured connections with appropriate fasteners and mastic sealant, and replaced damaged insulation sections to restore proper airflow and thermal efficiency to affected zone.
Ocean Pines, MD 21811
Responded to no cooling complaint on 4-year-old upstairs system located in attic. Upon inspection, found improperly sized filter rack causing airflow restriction. Measured existing installation and determined correct dimensions for replacement filter rack (21"D x 17½" x 20"). Installed new properly-sized filter rack on top of unit to restore adequate airflow to system. System tested and confirmed cooling operation restored to normal parameters.
Responded to no cooling complaint on 4-year-old upstairs system located in attic. Upon inspection, found improperly sized filter rack causing airflow restriction. Measured existing installation and determined correct dimensions for replacement filter rack (21"D x 17½" x 20"). Installed new properly-sized filter rack on top of unit to restore adequate airflow to system. System tested and confirmed cooling operation restored to normal parameters.
Dennis K.
Dennis K. Checked in
Responded to no cooling complaint on 4-year-old upstairs system located in attic. Upon inspection, found improperly sized filter rack causing airflow restriction. Measured existing installation and determined correct dimensions for replacement filter rack (21"D x 17½" x 20"). Installed new properly-sized filter rack on top of unit to restore adequate airflow to system. System tested and confirmed cooling operation restored to normal parameters.
Ocean Pines, MD 21811
Removed and disposed of existing furnace equipment. Installed one Lennox EL297DF090XV60CK variable speed gas furnace with ECM blower motor. Fabricated and installed metal duct transitions to adapt new unit to existing ductwork. Reused existing electrical connections, condensate drain lines, and power supply. Performed combustion analysis and verified draft pressure readings at 8.49 inches water column and 1.70 inches water column to ensure proper venting operation. System tested and operational. This installation follows recent heat pump and coil replacement where faulty gas valve was identified. One-year service contract initiated from installation date.
Removed and disposed of existing furnace equipment. Installed one Lennox EL297DF090XV60CK variable speed gas furnace with ECM blower motor. Fabricated and installed metal duct transitions to adapt new unit to existing ductwork. Reused existing electrical connections, condensate drain lines, and power supply. Performed combustion analysis and verified draft pressure readings at 8.49 inches water column and 1.70 inches water column to ensure proper venting operation. System tested and operational. This installation follows recent heat pump and coil replacement where faulty gas valve was identified. One-year service contract initiated from installation date.
Federico P.
Federico P. Checked in
Removed and disposed of existing furnace equipment. Installed one Lennox EL297DF090XV60CK variable speed gas furnace with ECM blower motor. Fabricated and installed metal duct transitions to adapt new unit to existing ductwork. Reused existing electrical connections, condensate drain lines, and power supply. Performed combustion analysis and verified draft pressure readings at 8.49 inches water column and 1.70 inches water column to ensure proper venting operation. System tested and operational. This installation follows recent heat pump and coil replacement where faulty gas valve was identified. One-year service contract initiated from installation date.
Ocean Pines, MD 21811
Responded to service call for leaking outdoor spigot. Upon arrival, assessed the exterior water fixture and identified source of leak. Completed necessary repairs to resolve the water leakage issue and restore proper function to the outdoor spigot.
Responded to service call for leaking outdoor spigot. Upon arrival, assessed the exterior water fixture and identified source of leak. Completed necessary repairs to resolve the water leakage issue and restore proper function to the outdoor spigot.
Coty B.
Coty B. Checked in
Responded to service call for leaking outdoor spigot. Upon arrival, assessed the exterior water fixture and identified source of leak. Completed necessary repairs to resolve the water leakage issue and restore proper function to the outdoor spigot.
Ocean Pines, MD 21811
Responded to no cooling complaint on Rheem HVAC system. Upon arrival, confirmed inadequate cooling performance during high ambient temperature conditions. Performed diagnostic testing including temperature differential measurements at supply and return, verified refrigerant charge levels, and inspected ductwork insulation in attic space for proper sealing and thermal efficiency. System evaluated and measurements documented with thermal imaging equipment to identify performance issues affecting cooling capacity during peak load conditions.
Responded to no cooling complaint on Rheem HVAC system. Upon arrival, confirmed inadequate cooling performance during high ambient temperature conditions. Performed diagnostic testing including temperature differential measurements at supply and return, verified refrigerant charge levels, and inspected ductwork insulation in attic space for proper sealing and thermal efficiency. System evaluated and measurements documented with thermal imaging equipment to identify performance issues affecting cooling capacity during peak load conditions.
Gardo V.
Gardo V. Checked in
Responded to no cooling complaint on Rheem HVAC system. Upon arrival, confirmed inadequate cooling performance during high ambient temperature conditions. Performed diagnostic testing including temperature differential measurements at supply and return, verified refrigerant charge levels, and inspected ductwork insulation in attic space for proper sealing and thermal efficiency. System evaluated and measurements documented with thermal imaging equipment to identify performance issues affecting cooling capacity during peak load conditions.
Ocean Pines, MD 21811
Responded to recurring condensate leak issue with water running down interior walls from mini split system. Upon inspection, found excessive moisture accumulation on refrigerant lines and condensate drainage components, indicating improper drainage or blockage in the condensate removal system. Documented conditions with photos showing water droplets forming on both insulated and uninsulated piping within the line set chase, confirming active condensation problem requiring immediate attention to prevent further water damage and customer dissatisfaction.
Responded to recurring condensate leak issue with water running down interior walls from mini split system. Upon inspection, found excessive moisture accumulation on refrigerant lines and condensate drainage components, indicating improper drainage or blockage in the condensate removal system. Documented conditions with photos showing water droplets forming on both insulated and uninsulated piping within the line set chase, confirming active condensation problem requiring immediate attention to prevent further water damage and customer dissatisfaction.
Dennis K.
Dennis K. Checked in
Responded to recurring condensate leak issue with water running down interior walls from mini split system. Upon inspection, found excessive moisture accumulation on refrigerant lines and condensate drainage components, indicating improper drainage or blockage in the condensate removal system. Documented conditions with photos showing water droplets forming on both insulated and uninsulated piping within the line set chase, confirming active condensation problem requiring immediate attention to prevent further water damage and customer dissatisfaction.
Ocean Pines, MD 21811
Completed full HVAC system replacement including removal and disposal of old equipment. Installed Lennox ML14KP1-036 3-ton 14 SEER heat pump on pressure-treated wood platform with new outdoor disconnect and electrical whip. Installed Lennox CBK45UHET-036 air handler in crawlspace with 10 kW electric heat pack and Honeywell digital thermostat. Fabricated and installed metal duct transitions to adapt new equipment to existing ductwork. Reused existing electrical service, condensate drain lines, and power connections where applicable. Filter grille location: 14x30x1. All equipment tested and operational upon completion.
Completed full HVAC system replacement including removal and disposal of old equipment. Installed Lennox ML14KP1-036 3-ton 14 SEER heat pump on pressure-treated wood platform with new outdoor disconnect and electrical whip. Installed Lennox CBK45UHET-036 air handler in crawlspace with 10 kW electric heat pack and Honeywell digital thermostat. Fabricated and installed metal duct transitions to adapt new equipment to existing ductwork. Reused existing electrical service, condensate drain lines, and power connections where applicable. Filter grille location: 14x30x1. All equipment tested and operational upon completion.
Federico P.
Federico P. Checked in
Completed full HVAC system replacement including removal and disposal of old equipment. Installed Lennox ML14KP1-036 3-ton 14 SEER heat pump on pressure-treated wood platform with new outdoor disconnect and electrical whip. Installed Lennox CBK45UHET-036 air handler in crawlspace with 10 kW electric heat pack and Honeywell digital thermostat. Fabricated and installed metal duct transitions to adapt new equipment to existing ductwork. Reused existing electrical service, condensate drain lines, and power connections where applicable. Filter grille location: 14x30x1. All equipment tested and operational upon completion.
Ocean Pines, MD 21811
Completed full HVAC system replacement for upstairs zone. Removed and properly disposed of existing equipment. Installed new Lennox EL19KPV-036 3-ton 19 SEER variable speed heat pump outdoor unit on pressure-treated wood platform against exterior wall. Mounted CBK45UHVT-036 variable speed air handler indoors with filter access at unit. Integrated Lennox 10kW electric heat pack for supplemental heating capacity. Fabricated and installed metal duct transitions to adapt new equipment to existing ductwork infrastructure. Reused existing refrigerant lines and condensate drain piping. Replaced outdoor electrical disconnect and electrical whip to meet current code requirements. Installed Honeywell digital WiFi thermostat for remote system control and monitoring. Verified all electrical connections, refrigerant charge, airflow, and system operation. Unit tested and operating to manufacturer specifications. System ready for service.
Completed full HVAC system replacement for upstairs zone. Removed and properly disposed of existing equipment. Installed new Lennox EL19KPV-036 3-ton 19 SEER variable speed heat pump outdoor unit on pressure-treated wood platform against exterior wall. Mounted CBK45UHVT-036 variable speed air handler indoors with filter access at unit. Integrated Lennox 10kW electric heat pack for supplemental heating capacity. Fabricated and installed metal duct transitions to adapt new equipment to existing ductwork infrastructure. Reused existing refrigerant lines and condensate drain piping. Replaced outdoor electrical disconnect and electrical whip to meet current code requirements. Installed Honeywell digital WiFi thermostat for remote system control and monitoring. Verified all electrical connections, refrigerant charge, airflow, and system operation. Unit tested and operating to manufacturer specifications. System ready for service.
Federico P.
Federico P. Checked in
Completed full HVAC system replacement for upstairs zone. Removed and properly disposed of existing equipment. Installed new Lennox EL19KPV-036 3-ton 19 SEER variable speed heat pump outdoor unit on pressure-treated wood platform against exterior wall. Mounted CBK45UHVT-036 variable speed air handler indoors with filter access at unit. Integrated Lennox 10kW electric heat pack for supplemental heating capacity. Fabricated and installed metal duct transitions to adapt new equipment to existing ductwork infrastructure. Reused existing refrigerant lines and condensate drain piping. Replaced outdoor electrical disconnect and electrical whip to meet current code requirements. Installed Honeywell digital WiFi thermostat for remote system control and monitoring. Verified all electrical connections, refrigerant charge, airflow, and system operation. Unit tested and operating to manufacturer specifications. System ready for service.
Ocean Pines, MD 21811
Completed preventive maintenance on two cooling systems. Verified thermostat operation showing 76°F setpoint with system in cooling mode and fan set to auto. Measured supply air temperature at 73.3°F at ductwork, confirming proper cooling output and system performance within normal operating parameters.
Completed preventive maintenance on two cooling systems. Verified thermostat operation showing 76°F setpoint with system in cooling mode and fan set to auto. Measured supply air temperature at 73.3°F at ductwork, confirming proper cooling output and system performance within normal operating parameters.
Dylan L.
Dylan L. Checked in
Completed preventive maintenance on two cooling systems. Verified thermostat operation showing 76°F setpoint with system in cooling mode and fan set to auto. Measured supply air temperature at 73.3°F at ductwork, confirming proper cooling output and system performance within normal operating parameters.
Ocean Pines, MD 21811
Responded to no cooling complaint on 10+ year old system. Performed diagnostic evaluation of outdoor condensing unit and indoor air handler located in attic space. Inspected equipment operation, refrigerant lines, electrical connections, and overall system condition. Documented equipment with photos for service records. Customer acknowledged billable repair authorization with payment method on file.
Responded to no cooling complaint on 10+ year old system. Performed diagnostic evaluation of outdoor condensing unit and indoor air handler located in attic space. Inspected equipment operation, refrigerant lines, electrical connections, and overall system condition. Documented equipment with photos for service records. Customer acknowledged billable repair authorization with payment method on file.
Dennis K.
Dennis K. Checked in
Responded to no cooling complaint on 10+ year old system. Performed diagnostic evaluation of outdoor condensing unit and indoor air handler located in attic space. Inspected equipment operation, refrigerant lines, electrical connections, and overall system condition. Documented equipment with photos for service records. Customer acknowledged billable repair authorization with payment method on file.
Ocean Pines, MD 21811
Ocean Pines, MD - Responded to no cooling call on outdoor condensing unit. Upon arrival, found unit not operating. Conducted diagnostic evaluation of electrical components, refrigerant lines, and disconnect box. Verified proper connections between outdoor unit and building system, inspected refrigerant line insulation and electrical conduit routing. System restored to proper operation with cooling functionality confirmed before departure.
Dennis K.
Dennis K. Checked in
Responded to no cooling call on outdoor condensing unit. Upon arrival, found unit not operating. Conducted diagnostic evaluation of electrical components, refrigerant lines, and disconnect box. Verified proper connections between outdoor unit and building system, inspected refrigerant line insulation and electrical conduit routing. System restored to proper operation with cooling functionality confirmed before departure.
Ocean Pines, MD 21811
# HVAC Service Call - No Cooling Issue

Responded to service call for air conditioning system running continuously without achieving desired cooling. Upon arrival, found thermostat set to 73°F with indoor temperature reading 76°F and rising. Verified complaint that system had been running constantly with no temperature reduction.

Performed initial diagnostic assessment at thermostat location. Confirmed thermostat display showed "Cool On" mode with fan set to auto operation. Verified thermostat was calling for cooling and communicating properly with HVAC system. Used digital temperature measurement device to confirm ambient temperature readings matched thermostat display at 73.3°F in the conditioned space.

Inspected indoor air handler components and ductwork in mechanical area. Observed supply duct insulation and verified airflow from system. Documented current operating conditions with temperature measurements and thermostat settings for service records.

System evaluation revealed u
# HVAC Service Call - No Cooling Issue

Responded to service call for air conditioning system running continuously without achieving desired cooling. Upon arrival, found thermostat set to 73°F with indoor temperature reading 76°F and rising. Verified complaint that system had been running constantly with no temperature reduction.

Performed initial diagnostic assessment at thermostat location. Confirmed thermostat display showed "Cool On" mode with fan set to auto operation. Verified thermostat was calling for cooling and communicating properly with HVAC system. Used digital temperature measurement device to confirm ambient temperature readings matched thermostat display at 73.3°F in the conditioned space.

Inspected indoor air handler components and ductwork in mechanical area. Observed supply duct insulation and verified airflow from system. Documented current operating conditions with temperature measurements and thermostat settings for service records.

System evaluation revealed u
Dylan L.
Dylan L. Checked in
# HVAC Service Call - No Cooling Issue Responded to service call for air conditioning system running continuously without achieving desired cooling. Upon arrival, found thermostat set to 73°F with indoor temperature reading 76°F and rising. Verified complaint that system had been running constantly with no temperature reduction. Performed initial diagnostic assessment at thermostat location. Confirmed thermostat display showed "Cool On" mode with fan set to auto operation. Verified thermostat was calling for cooling and communicating properly with HVAC system. Used digital temperature measurement device to confirm ambient temperature readings matched thermostat display at 73.3°F in the conditioned space. Inspected indoor air handler components and ductwork in mechanical area. Observed supply duct insulation and verified airflow from system. Documented current operating conditions with temperature measurements and thermostat settings for service records. System evaluation revealed u
Ocean Pines, MD 21811
Performed seasonal cooling system maintenance check on outdoor condensing unit and indoor air handling equipment. Inspected R410A outdoor unit showing normal weathering, verified nameplate specifications and serial number documentation, and examined attic-mounted HVAC components including supply ductwork and insulated flex runs for proper installation and condition.
Performed seasonal cooling system maintenance check on outdoor condensing unit and indoor air handling equipment. Inspected R410A outdoor unit showing normal weathering, verified nameplate specifications and serial number documentation, and examined attic-mounted HVAC components including supply ductwork and insulated flex runs for proper installation and condition.
Dennis K.
Dennis K. Checked in
Performed seasonal cooling system maintenance check on outdoor condensing unit and indoor air handling equipment. Inspected R410A outdoor unit showing normal weathering, verified nameplate specifications and serial number documentation, and examined attic-mounted HVAC components including supply ductwork and insulated flex runs for proper installation and condition.
Ocean Pines, MD 21811
Installed owner-supplied evaporator coil to existing R410A heat pump system, utilizing the existing outdoor unit and thermostat. Completed installation in residential garage location with all components properly connected to ductwork, condensate drainage lines, and electrical systems, ensuring compatibility with existing R410A refrigerant system.
Installed owner-supplied evaporator coil to existing R410A heat pump system, utilizing the existing outdoor unit and thermostat. Completed installation in residential garage location with all components properly connected to ductwork, condensate drainage lines, and electrical systems, ensuring compatibility with existing R410A refrigerant system.
Frankie C.
Frankie C. Checked in
Installed owner-supplied evaporator coil to existing R410A heat pump system, utilizing the existing outdoor unit and thermostat. Completed installation in residential garage location with all components properly connected to ductwork, condensate drainage lines, and electrical systems, ensuring compatibility with existing R410A refrigerant system.
Ocean Pines, MD 21811
Completed routine cooling maintenance visit on residential air conditioning system. Performed comprehensive inspection of outdoor condensing unit, verified proper operation of all components, and measured discharge line temperature at 150°F, which falls within normal operating parameters for R-410A refrigerant system. Unit is functioning correctly with no issues identified. All manufacturer specifications confirmed, equipment operating efficiently, and system ready for continued cooling season operation.
Completed routine cooling maintenance visit on residential air conditioning system. Performed comprehensive inspection of outdoor condensing unit, verified proper operation of all components, and measured discharge line temperature at 150°F, which falls within normal operating parameters for R-410A refrigerant system. Unit is functioning correctly with no issues identified. All manufacturer specifications confirmed, equipment operating efficiently, and system ready for continued cooling season operation.
Dylan L.
Dylan L. Checked in
Completed routine cooling maintenance visit on residential air conditioning system. Performed comprehensive inspection of outdoor condensing unit, verified proper operation of all components, and measured discharge line temperature at 150°F, which falls within normal operating parameters for R-410A refrigerant system. Unit is functioning correctly with no issues identified. All manufacturer specifications confirmed, equipment operating efficiently, and system ready for continued cooling season operation.
Ocean Pines, MD 21811
# HVAC Maintenance - Heating System Service

Performed routine heating maintenance visit on residential HVAC system. Verified thermostat operation and confirmed system settings, with unit displaying 71°F in heating mode with fan circulation active. Measured electrical current draw at 17.2 amps using clamp meter to verify proper system operation and ensure equipment is functioning within normal parameters.
# HVAC Maintenance - Heating System Service

Performed routine heating maintenance visit on residential HVAC system. Verified thermostat operation and confirmed system settings, with unit displaying 71°F in heating mode with fan circulation active. Measured electrical current draw at 17.2 amps using clamp meter to verify proper system operation and ensure equipment is functioning within normal parameters.
Dylan L.
Dylan L. Checked in
# HVAC Maintenance - Heating System Service Performed routine heating maintenance visit on residential HVAC system. Verified thermostat operation and confirmed system settings, with unit displaying 71°F in heating mode with fan circulation active. Measured electrical current draw at 17.2 amps using clamp meter to verify proper system operation and ensure equipment is functioning within normal parameters.
Ocean Pines, MD 21811
Ocean Pines, MD - Completed routine cooling maintenance visit on system 1 of 2. Performed standard preventive maintenance procedures and inspected ComfortNet Control System thermostat, which was functioning properly and displaying current indoor temperature of 77°F with setpoint of 75°F. Noted outdoor sensor battery replacement alert displayed on thermostat screen and documented for follow-up.
Dylan L.
Dylan L. Checked in
Completed routine cooling maintenance visit on system 1 of 2. Performed standard preventive maintenance procedures and inspected ComfortNet Control System thermostat, which was functioning properly and displaying current indoor temperature of 77°F with setpoint of 75°F. Noted outdoor sensor battery replacement alert displayed on thermostat screen and documented for follow-up.
Ocean Pines, MD 21811

Call or Click to Schedule an Appointment Today!

100% Satisfaction Guaranteed

Compliance Settings
Increase Font Size
Grayscale
Simplified Font
Underline Links
Highlight Links
Reset
Close