Rehoboth Beach, DE Furnace Repair & Service
The HVAC and plumbing systems inside your home play a pivotal role in your life and providing you comfort. Custom Mechanical, a full-service contractor in Rehoboth Beach, Delaware, helps homeowners improve their quality of life by putting their comfort needs first. For more than four decades, we have continued to build on our reputation as being the best full-service contractor in Delaware.
Air Conditioning and Furnace Contractor in Rehoboth Beach, DE
Custom Mechanical recommends investing in an annual maintenance plan to ensure your air conditioner remains in good health. With an annual maintenance plan, our technicians will take care of any repairs and upkeep to ensure your air conditioner not only operates efficiently but also has a longer life.
Another benefit of an annual maintenance plan is that it'll also cover your heating system. During the cold winters in Delaware, you want to be sure you and your family are warm and cozy in your home. Keep in mind that Custom Mechanical also offers 24/7 emergency service, in case you do have a heating problem.
Plumbing Contractor in Rehoboth Beach, DE
While most homeowners leave the HVAC repairs to the professionals, many try to fix plumbing problems on their own without proper training. This can lead to a dangerous situation, where you could be risking expensive home repairs or even your health.
Custom Mechanical's technicians have the education and experience to complete any job to the highest of standards while adhering to all safety guidelines. From servicing your water heater to remodeling your bathroom, we offer a full range of plumbing services at a fair price.
Custom Mechanical's team of home service experts is proud to offer HVAC, and plumbing services to residents in Rehoboth Beach, Delaware. Whether you need a repair or a replacement, or if you just have a question, contact us today.
Recent Jobs and Reviews in Rehoboth Beach, DE
Rehoboth Beach, DE at a glance
Custom Mechanical has completed 20 jobs in Rehoboth Beach, DE between March 2026 and April 2026.
The most recent job was on April 6, 2026.
Job Locations and Reviews
Performed comprehensive cooling system maintenance on multi-zone HVAC system. Conducted electrical diagnostics using clamp meter to verify proper amperage draw and voltage readings across multiple units, confirming all systems operating within manufacturer specifications. Inspected control boards, wiring connections, and electrical components in all zones to ensure safe and efficient operation for the cooling season.
Installed a 50-gallon tall residential electric water heater (model RE250T61) in utility closet with complete plumbing connections. Installation included 22-inch drain pan for leak protection, thermal expansion tank mounted to wall with brass fittings, dual 18-inch flexible water connectors, brass nipples (3/4" x 2" and 3/4" x 6"), high-temperature rated 3/4" male adapters, 3/4" brass 90-degree elbow, and 3/4" brass tee for proper water distribution. Connected copper supply lines and verified all connections for proper operation and leak-free performance.
Completed full HVAC system replacement including removal and disposal of existing equipment. Installed new Carrier 27SCA530A003 2.5-ton 15 SEER heat pump outdoor unit on pressure-treated wood platform, Carrier FJ5ANXB30L00 air handler, and Carrier FF2601C10 10kw electric heat pack. Fabricated and installed metal duct transitions to adapt new equipment to existing ductwork. Replaced outdoor disconnect and electrical whip while reusing existing condensation lines and power supply. Installed Honeywell TH6320WF digital WiFi thermostat for system control. Performed system startup, tested all electrical connections and refrigerant levels, and verified proper operation of heating and cooling modes. Unit filter installed at air handler location. System commissioned and left in full working order with one-year parts warranty from installation date.
Responded to no cooling complaint on downstairs system with outdoor unit not running. Upon arrival, inspected Trane TEM4A0C42S41SAA air handler manufactured April 2016 utilizing R-410A refrigerant. Documented equipment nameplate specifications including 208-230V electrical requirements and verified unit configuration. Diagnosed outdoor condensing unit failure to operate and performed necessary repairs to restore cooling operation to the system.
Responded to no hot water complaint for 50-gallon electric water heater located in closet behind kitchen serving front half of residence. Upon inspection, confirmed unit was inoperative with no indicator light illuminated. Identified water heater as AO Smith model EE3J50RD045V manufactured in 1999, which had reached end of serviceable life after 27 years of operation. Documented existing installation conditions including copper supply piping connections and electrical configuration. Provided estimate for replacement of failed electric water heater unit with new equipment to restore hot water service to kitchen and front portion of home.
Performed routine cooling system maintenance on two residential air conditioning units. Inspected thermostat operation and verified proper display function and control settings. Evaluated both outdoor condenser units, confirmed fan operation, checked mounting stability on concrete pads, and assessed overall equipment condition with minor surface rust noted on mounting hardware but no operational concerns identified.
Removed and disposed of existing second floor HVAC system. Installed new 2-ton 17 SEER heat pump outdoor unit on platform with 5A6H7024 condenser and 5TEM6B02 variable speed fan coil unit in drain pan with shut-off valve. Installed 10KW electric heat strip with breaker (HTR1510BRKR) for supplemental heating. Flushed, pressure tested, and recharged refrigeration lines to manufacturer specifications. Furnished and installed electrical whip with disconnect for outdoor unit. Installed TH6320WF2003 WiFi programmable thermostat for remote system control and monitoring. Extended maintenance contract coverage by one year on both systems in residence. All equipment tested and operational upon completion.
Responded to no heat call where system tripped breaker after switching from cooling to heating mode. Upon arrival, utilized thermal imaging camera to inspect electrical panel and identify potential hot spots or failing breaker connections. Thermal scan revealed temperature differential at breaker location, with readings showing 72.5°F maximum temperature at affected circuit. Reset tripped breaker, verified proper amperage draw, and confirmed system restored to normal heating operation with no further electrical issues detected.
Responded to emergency call for burst water pipe outside residence. Isolated water supply and replaced damaged section of galvanized plumbing valve that showed significant corrosion and mineral buildup. Installed new brass fitting to restore proper water flow and prevent future leakage.
Successfully installed a Mitsubishi mini-split system, including mounting the MUZ-WX12NL heat pump outdoor unit on a wall bracket and installing the MSZ-WX12NL fan coil unit above the sunroom sliding glass door. Completed all necessary refrigeration, condensation, and low voltage line installations through the crawlspace to the outdoor unit, concealed exterior lines in white PVC covering, and installed surge disconnect.
Replaced defective furnace valve on propane system that was previously shut off due to malfunction. Reconnected and properly terminated electrical wiring with appropriate wire nuts. System successfully restored to normal operation after valve replacement.
Conducted assessment of 15-year-old Trane heat pump system located in utility closet for potential replacement. Documented existing installation including indoor air handler in utility closet adjacent to Bradford White water heater with expansion tank. Exterior inspection revealed two outdoor units (primary Trane condenser and secondary unit) installed on ground level against vinyl siding, both appearing operational but at end of useful service life.
Conducted system evaluation for potential replacement of 26-year-old furnace, 9-year-old indoor coil and outdoor unit. Assessed existing BMPlus2000 control board and ceiling return configuration for compatibility with requested heat pump conversion. Customer previously received quote for furnace replacement only but now desires complete system replacement with heat pump option.
Successfully removed and disposed of old water heating system and installed new Bradford White RE250T6 50-gallon electric water heater with expansion tank. Installation included new 23" x 20 3/4" metal drain pan without drain, brass fittings, and flexible connections. System was properly connected and tested for operation.
Performed routine cooling system maintenance check, verifying temperature differentials with Klein Tools IR07 thermometer. Readings showed 21.2°C supply temperature and 45.5°C at system probe point, confirming proper operation within manufacturer specifications. Customer is obtaining replacement filters to be installed at unit location.
Performed scheduled heating maintenance service on two systems. Inspected blower motor assembly and wheel for proper operation, noting intact squirrel cage fan with even blade spacing. Examined electrical connections and circuit board components, confirming all wiring was properly secured and organized with no signs of damage or wear.
Completed installation of a complete American Standard HVAC system, including a 2.5-ton 14 SEER heat pump, air handler, 10kw electric heat kit, and digital WiFi thermostat. Removed and disposed of old equipment, installed metal duct transitions, reused existing utilities where appropriate, replaced outdoor disconnect and electrical whip, and positioned outdoor unit on existing stand. System was properly mounted on wooden deck platform with all necessary electrical conduits and refrigerant lines connected according to manufacturer specifications.
Conducted site evaluation of existing HVAC system, including inspection of weathered outdoor condensing unit mounted on deteriorating wooden platform and assessment of programmable thermostat (displaying 70°F, 58% humidity). Prepared replacement estimate for complete system upgrade due to age-related efficiency decline and platform structural concerns.
Diagnosed and replaced seized inducer motor in York furnace model PCG4A361002X1A. Multimeter testing confirmed 1.96A draw on the failed component. Extensive corrosion was observed throughout the system, particularly on the housing and base plate where moisture had accumulated.
Responded to service call for heat pump with no heat. Found outdoor unit completely encased in ice with defrost cycle failure. Activated emergency heat mode to restore temporary heating while allowing system to defrost. Verified thermostat operation (showing 67°F) and educated customer on proper system operation during recovery period.